A valve enquiry may state only two details: DN300 and 10 bar. That sounds specific, but it is still not enough to select a pneumatic knife gate valve.

The actuator must overcome the force created by differential pressure across the closed gate, together with friction from the seat and packing. If pressure is similar on both sides, the load may be limited. During isolation or discharge, however, downstream pressure can fall and expose the valve to a much higher differential pressure.

Available air pressure matters as well. An actuator selected at 6 bar may not produce the required thrust if the plant air supply falls during peak demand. The calculation should therefore use the lowest reliable air pressure available at the valve.

Simply fitting a larger cylinder does not solve every problem. The valve body, gate, seat, packing and actuator mounting must all be suitable for the same operating conditions. Slurry composition, solids concentration and cycling frequency can further affect the required configuration.

When reviewing a pneumatic knife gate valve, define the maximum inlet and outlet pressures, medium, temperature, valve size, operating frequency and minimum air supply.

10 bar pipeline pressure is a starting point. The actual pressure difference during closure determines what the valve must handle.